Syringe filters are a cost-effective way to improve the quality of HPLC analysis, improve consistency, extend column life and reduce maintenance. By removing particulates before the sample enters the column, Navigator syringe filters allow unimpeded flow. Without particulates to create obstructions, your column will work more efficiently and last longer.
In addition to HPLC, syringe filters have a multitude of other applications. A syringe filter adds a few minutes and a minimal expense to your testing process, but you will see a big return on your investment.
Product Name | Diameter (mm) | Pore Size(µm) | Media Material | Package |
Syringe Filter | 13 | 0.45 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 13 | 0.22 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | Nylon 6 | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | Nylon 6 | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 13 | 0.45 | PTFE | 100 Pcs/pack |
Syringe Filter | 13 | 0.22 | PTFE | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | PTFE | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | PTFE | 100 Pcs/pack |
Syringe Filter | 13 | 0.45 | PVDF | 100 Pcs/pack |
Syringe Filter | 13 | 0.22 | PVDF | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | PVDF | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | PVDF | 100 Pcs/pack |
Pore size | PES 0.45 | PES 0.2 | Nylon 66 0.45 | Nylon 66 0.2 |
Membrane thickness(um) | 114.3-165.1 | 129.5-162.6 | 114.8-170.2 | 139.7-177.8 |
Bubble Point | 2.48-3.31 | 3.65-4.76 | 2.21-2.48 | 3.52-3.86 |
Effective Filtration Area | 0.8cm2 | 0.8cm2 | 0.8cm2 | 0.8cm2 |
Hold-up Volume(with air purge) | <15ul | <15ul | <15ul | <15ul |
Max.Operating Pressure | 6.9bar | 6.9bar | 6.9bar | 6.9bar |
Typical Water Flow Rate(ml/min/cm2,0.7bar 10Psi) | 38-100 | 19.3-34.6 | - | - |
Sample Volume | <10ml | <10ml | <10ml | <10ml |
Pore size | PES 0.45 | PES 0.2 | Nylon 66 0.45 | Nylon 66 0.2 |
Membrane thickness(um) | 114.3-165.1 | 129.5-162.6 | 114.8-170.2 | 139.7-177.8 |
Bubble Point | 2.48-3.31 | 3.65-4.76 | 2.21-2.48 | 3.52-3.86 |
Effective Filtration Area | 3.8cm2 | 3.8cm2 | 3.8cm2 | 3.8cm2 |
Hold-up Volume(with air purge) | <125ul | <125ul | <125ul | <125ul |
Max. Operating Pressure | 5.2bar | 5.2bar | 5.2bar | 5.2bar |
Typical Water Flow Rate(ml/min/cm2,0.7bar 10Psi) | 38-100 | 19.3-34.6 | - | - |
Sample Volume | <150ml | <150ml | <150ml | <150ml |
The double layer syringe filter is specifically designed for high particulate loaded samples. Constructed of polypropylene housing with a prefiltration made of glass microfiber, these filters eliminate sample contamination and allow you to filter even the most difficult samples with less hand pressure.
The ideal product for heavily particulate-laden samples found in :
Product Name | Dia (mm) | Pore Size (µm) | Media Material | Package |
Syringe Filter | 13 | 0.45 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 13 | 0.22 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | Nylon 6 | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | Nylon 6 | 100 Pcs/pack |
Syringe Filter | 25 | 0.45 | Nylon 66 | 100 Pcs/pack |
Syringe Filter | 25 | 0.22 | Nylon 66 | 100 Pcs/pack |